Proof load sits below the yield point and above the service load, so a part that passes proves it is sound without being destroyed. It is the check behind a class marking: a bolt that deforms at proof load does not meet its class, even if it would not break until a higher load.
Ask for the proof-load value and the test standard when the joint is critical, and confirm that the test certificate refers to the same class and size as the delivered parts. Treat proof load as a quality gate, not as a permitted service load.